PARA-CHEM SOUTHERN INC -- KRALOY PVC PIPE CEMENT -- 8040-00N036357
===================== Product Identification =====================
Product ID:KRALOY PVC PIPE CEMENT
MSDS Date:12/03/1990
FSC:8040
NIIN:00N036357
MSDS Number: BQQWP
=== Responsible Party ===
Company Name:PARA-CHEM SOUTHERN INC
Box:127
City:SIMPSONVILLE
State:SC
ZIP:29681
Country:US
Info Phone Num:803-967-7691
Emergency Phone Num:803-967-7691
Preparer's Name:B.L. EUDY
CAGE:15865
=== Contractor Identification ===
Company Name:PARA CHEM
Box:127
City:SIMPSONVILLE
State:SC
ZIP:29681
Country:US
Phone:864-967-7691
CAGE:15934
Company Name:PARA-CHEM SOUTHERN INC
Box:127
City:SIMPSONVILLE
State:SC
ZIP:29681
Country:US
Phone:(803) 967-7691
CAGE:15865
============= Composition/Information on Ingredients =============
Ingred Name:FURAN, TETRAHYDRO; (TETRAHYDROFURAN) (SARA III)
CAS:109-99-9
RTECS #:LU5950000
Fraction by Wt: 23%
OSHA PEL:200 PPM;250 STEL
ACGIH TLV:200 PPM;250 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA III)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: 46%
OSHA PEL:200 PPM;300 STEL
ACGIH TLV:200 PPM;300 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:CYCLOHEXANONE (SARA III)
CAS:108-94-1
RTECS #:GW1050000
Fraction by Wt: 17%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:VOLATILE ORGANIC COMPOUNDS:773 G/L.
RTECS #:9999999VO
Ingred Name:SUPDAT:BRTHG OF VAPS RELEASED DURING PROCESS. DO NOT
WELD/FLAME-CUT EMPTY DRUM. KEEP OUT OF REACH OF (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5:CHILDREN. PROD AS SUPPLIED IS A LIQ, & THERE ARE NO
DUST HAZ FROM POWDER IN IT. WHEN PROD IS PROCESSED, (ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6:POWDERS SHOULD BE ENCAPSULATED. USER MUST DETERMINE
IF THERE IS A DUST HAZ BECAUSE OF PROCESS USED OR (ING 8)
RTECS #:9999999ZZ
Ingred Name:ING 7:END USE OF DRIED MATERIALS.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:LIQ CAUSES SEV IRRIT. VAPS CAUSE
SLIGHT TO MOD IRRIT. SKIN:LIQ/VAP CAUSES MOD IRRIT. INHAL:CAN CAUSE
NOSE & THROAT IRRIT, HDCH, NAUS, DROWS, DIZZ & INCOORDINATION.
INGEST:MOD TOX. MAY CAUSE NAUS, VOMIT & DIARR.
TETRAHYDROFURAN:ATTACKSSKIN, EYES, RESP SYS & CNS. OVEREXPOS HAS
BEEN FOUND TO CAUSE LIVER (EFTS OF OVE
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:ABNORM & KIDNEY DMG TO LAB ANIMALS.
MEK:ATTACKS EYES, SKIN, LUNGS & CNS. CYCLOHEXANONE:ATTACKS SKIN
EYES, LUNGS AND CNS. OVEREXPOS HAS BEEN FOUND TO CAUSE LIVER ABNORM
& KIDNEY DMG TO LAB ANI MALS. REPORTS HAVE ASSOC RPTD/PRLNGD
OVEREXPOS TO SOLV W/PERM BRAIN & NERVOUS SYS DMG. INTENTIONAL
MISUSE BY (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MIN. CALL MD IF IRRIT
OCCURS. SKIN:WASH W/SOAP & WATER. CALL MD IF IRRIT OCCURS.
INHAL:MOVE TO FRESH AIR. IF BRTHG STOPS, ADMIN ARTIF RESP & CALL MD
IMMED. INGEST:TO CONSCIOUS PERSON, GIVE 2 GLASSES OF WATER. INDUCE
VOMIT & CALL MD IMMED. MED SURVEILLANCE:PREPLACEMENT & PERIODIC
EXAMINATIONS W/CONSIDERATION TO PTS OF ATTACK.
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:<20F,<-7C
Lower Limits:1.1%
Upper Limits:11.8%
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, AND ALCOHOL FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:ELIMINATE SOURCES OF IGNITION BECAUSE
VAPORS MAY TRAVEL ALONG GROUND OR BE MOVED BY VENTILATION.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE, DIKE AND DISPENSE SAND, SAWDUST OR
VERMICULITE. COLLECT AND PLACE IN WASTE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE ABOVE 40F & BELOW 100F, IN WELL
VENT AREA. NEVER USE PRESS TO EMPTY. DRUM IS NOT A PRESS VESSEL. DO
NOT TAKE INTERNALLY.
Other Precautions:KEEP CLOSURE TIGHT & CONTR UPRIGHT TO PREV LEAK.
STORE DRUM OUT OF SUN & AWAY FROM HEAT. RELIEVE INTERNAL DRUM PRESS
WHEN RECIEVED & AT LEAST ONCE WEEKLY THEREAFTER BY SLOWLY LOOSENING
CLOSURE. RETIGH TEN IMMED. (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF CONDITIONS EXIST WHERE PEL OR TLV MAY BE
EXCEEDED, WEAR A NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:USE SUFFICIENT VENTILATION, IN VOLUME AND PATTERN TO KEEP
AIR CONTAMINANT CONCENTRATION BELOW PEL AND TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOG W/F.L. FCSHLD (FP N
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXPOS:DELIBERATELY CONC & INHALING CONTENTS MAY BE
HARMFUL/FATAL. OTHER PREC:DO NOT STORE/USE NEAR HEAT, SPARKS/FLAME.
DRUMS OF MATL SHOULD BE GROUNDED & BONDED WHEN POURING. DO NOT
PUNCTU RE, DRAG/SLIDE CONTR. PREV PRLNGD/RPTD BRTHG OF VAP/SPRAY
MIST. CANNOT BE MADE NON-POISONOUS. AVOID CONT WITH OR (ING 5)
================== Physical/Chemical Properties ==================
HCC:F3
Boiling Pt:B.P. Text:>146F,>63C
Vapor Pres:86
Vapor Density:2.5
Spec Gravity:0.90 (H*2O = 1)
Evaporation Rate & Reference:5.7 (H*2O = 1)
Solubility in Water:MODERATE
Appearance and Odor:SLIGHT VISCOUS CLEAR LIQUID WITH KETONE ODOR.
Percent Volatiles by Volume:86
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:MAY FROM EXPLOSIVE PEROXIDE UPON LONG
STANDING IN AIR.
Hazardous Decomposition Products:BURNING CAN PRODUCE CARBON DIOXIDE,
CARBON MONOXIDE, WATER, HCL, CL*2 AND VAPORS OF CHEMICALS LISTED IN
INGREDIENT SECT.
Conditions to Avoid Polymerization:WILL OCCUR IN PRESENCE OF CATIONIC
INITIATORS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.