DRESSER INDUSTRIES INC -- LIONITE, ALUMINUM OXIDE, WHITE A/U -- 5350-00N066015
===================== Product Identification =====================
Product ID:LIONITE, ALUMINUM OXIDE, WHITE A/U
MSDS Date:09/13/1985
FSC:5350
NIIN:00N066015
MSDS Number: CBWDS
=== Responsible Party ===
Company Name:DRESSER INDUSTRIES INC
Address:2000 COLLAGE AVE
City:NIAGARA FALLS
State:NY
ZIP:14305
Country:US
Info Phone Num:716-286-1234
Emergency Phone Num:716-286-1234
Preparer's Name:DAVID K. BRAY
CAGE:29510
=== Contractor Identification ===
Company Name:DRESSER INDUSTRIES INC,CONSTRUCTION EQUIPMENT DIV
Address:E SUNNYSIDE AVE
Box:City:LIBERTYVILLE
State:IL
ZIP:60048-2944
Country:US
Phone:312-450-6565
CAGE:29510
Company Name:GENERAL ABRASIVE CO DIV OF DRESSER INDUSTRIES INC
Address:2000 COLLEGE AVE
Box:City:NIAGARA FALLS
State:NY
ZIP:14305-1734
Country:US
Phone:716-286-1234
CAGE:84330
============= Composition/Information on Ingredients =============
Ingred Name:ALUMINUM OXIDE (2:3); (ALUMINUM OXIDE) (AL*2O*3) (SARA
313)
CAS:1344-28-1
RTECS #:BD1200000
Fraction by Wt: 99.36%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
Ingred Name:SILICA GEL; (SILICON DIOXIDE) (SIO*2)
CAS:112945-52-5
RTECS #:VV7310000
Fraction by Wt: 0.09%
OSHA PEL:6 MG/M3
ACGIH TLV:10 MG/M3
Ingred Name:IRON (III) OXIDE; (IRON OXIDE) (FE*2O*3)
CAS:1309-37-1
RTECS #:NO7400000
Fraction by Wt: 0.14%
OSHA PEL:10 MG/M3 (FE)
ACGIH TLV:5 MG/M3 FUME (FE)
Ingred Name:MAGNESIUM OXIDE; (MGO)
CAS:1309-48-4
RTECS #:OM3850000
Fraction by Wt: 0.02%
OSHA PEL:15 MG/M3 PARTICULATE
ACGIH TLV:10 MG/M3 FUME
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOSURE TO EXCESSIVE AIRBORNE
CONCENTRATIONS MAY RESULT IN ACUTE RESPIRATORY DISORDERS.
INDIVIDUALS W/IMPAIRED PULMONARY FUNCTION SHOULD NOT BE SUBJECTED
TO EXCESSIVE AIRBORNE CONCENTRATIONS. SYMPTOM S OF EXCESSIVE
EXPOSURE MIGHT INCLUDE DEPOSITS OF MATERIAL IN EYES, EARS, NASAL
PASSAGES & IRRITATION (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OF MUCOUS MEMBRANES, EYES &
RESPIRATORY TRACT. IRRITATION OF SKIN MAY ALSO OCCUR DUE TO
MECHANICAL/CHEMICAL ACTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:REMOVE FROM EXPOSURE.
IRRIGATE W/COPIOUS QUANTITIES OF WATER FOR AT LEAST 15 MINUTES.
SEEK MEDICAL ATTENTION. SKIN:REMOVE FROM EXPOSURE. IRRIGATE
W/COPIOUS QUANTITIES OF WATER. SEEK MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NONFLAMMABLE.
================== Accidental Release Measures ==================
Spill Release Procedures:NORMAL PROCEDURES FOR INERT OR NUISANCE DUSTS
& PARTICULATES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NOTHING SPECIFIED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:UTILIZE NIOSH/MSHA APPROVED RESPIRATORY
PROTECTION FOR NUISANCE DUST.
Ventilation:UTILIZE LOCAL EXHAUST TO KEEP AIRBORNE CONCENTRATION BELOW
TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . ARM SLEEVES OR BARRIER CREAMS MAY BE
(SUPDAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PROT EQUIP:USEFUL IN THE PREVENTION OF DERMATITIS.
================== Physical/Chemical Properties ==================
Spec Gravity:3.95 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE TO OFF WHITE; NO ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN COMPLIANCE W/FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.