ADVANCE COATINGS CO -- UNSATURATED POLYESTER RESINS -- 8040-00N014044
=====================  Product Identification  =====================

Product ID:UNSATURATED POLYESTER RESINS
MSDS Date:05/19/1994
FSC:8040
NIIN:00N014044
MSDS Number: CGZNP
=== Responsible Party ===
Company Name:ADVANCE COATINGS CO
Address:42 DEPOT RD
City:WESTMINSTER
State:PA
ZIP:01473
Country:US
Info Phone Num:508-874-5921
Emergency Phone Num:508-874-5921;508-342-7459
CAGE:3K491
=== Contractor Identification ===
Company Name:ADVANCE COATINGS CO
Address:DEPOT ROAD
Box:City:WESTMINSTER
State:MA
ZIP:01473
Country:US
Phone:978-874-5921
CAGE:3K491

=============  Composition/Information on Ingredients  =============

Ingred Name:STYRENE; (STYRENE MONOMER) (SARA 313)
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: 40%
OSHA PEL:100 PPM
ACGIH TLV:S, 50 PPM/100 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:POLYESTER RESIN
Fraction by Wt: 60%
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:YES	 OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MODERATE IRRITANT. SIGNS AND
    SYMPTOMS OF EXPOSURE: OVEREXPOSURE MAY CAUSE IRRITATION TO THE
    RESPIRATORY TRACT AND TEARING OR REDNESS OF THE EYES. CHRONIC:
    LONGTERM EXPOSURE MAY CAUSE NAUSEA, LO SS OF APPETITE, CNS
    DEPRESSION AND GENERAL WEAKNESS.
Explanation of Carcinogenicity:STYRENE: IARC MONO, SUPP, VOL 60, PG
    233, 1994: GROUP 2B.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:THIS MATERIAL OR ITS EMISSIONS MAY
    AGGRAVATE PRE-EXISTING CNS DISORDERS.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . SKIN:FLUSH W/COPIOUS AMOUNTS OF
    WATER. CALL MD . INHAL: REMOVE TO FRESH AIR, REST, KEEP WARM AND
    GET MEDICAL ATTENTION. EYE CONT: FLUSH WITH WARM WATER FOR AT 
    LEAST 15 MINUTES. CONSULT PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:94.0F,34.4C
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:CARBON DIOXIDE, WATER FOG, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . FLASH POINT PENSKY MARTENS TESTER IS 88F.
Unusual Fire/Explosion Hazard:RESIN SPRAY FROM SPRAY GUN IS MORE
    FLAMMABLE THAN LIQUID RESIN. DRUMS OF RESIN IF IT HAS BEEN IN A
    FIRE MAY POLYMERIZE AND BUILD UP MORE INTERNAL HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ABSORB WITH VERMICULITE, SAWDUST OR RAGS OR
    SCOOP UP WITH SCOOPS OR SHOVELS. CLEAN UP RESIDUE WITH STRONG
    DETERGENT WATER SOLUTIONS. (GLOVES & GOGGLES). DO NOT ALLOW IN
    SEWER SYSTEM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID HEAT AND FLAMES. ALWAYS USE UP
    OLDEST LOTS FIRST.
Other Precautions:MATERIAL SHOULD LAST 6 MONTHS NOT OVER 75F.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED ORGANIC VAPOR RESPIRATORS ARE
    RECOMMENDED IF 50 PPM OF STYRENE IS EXCEEDED.
Ventilation:LOCAL EXHAUST: MAINTAIN VAPOR CONCENTRATION OF STYRENE
    BELOW 50 PPM.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:USE GOOD PERSONAL HYGIENE PRACTICE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:293F,145C
Vapor Pres:4.5 @ 20F
Vapor Density:3.6
Spec Gravity:1.25 0.15
Evaporation Rate & Reference:0.7 (BUTYL ACETATE =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:VISCOUS LIQUID, WITH ODOR OF STYRENE MONOMER.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NEVER MIX ORGANIC PEROXIDES WITH PROMPTERS. ADD SEPARATELY TO GELCOAT.
Stability Condition to Avoid:AVOID STORAGE OVER 75F. THIS MAY CAUSE
    PREMATURE OELATION.
Hazardous Decomposition Products:ON DECOMPOSITION EMITS ACRID FUMES.
    INCOMPLETE COMBUSTION PRODUCES CARBON MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:LAND FILL SOLIDS OR INCINERATE LIQUIDS WITH
    COMPATIBLE FUEL WHERE PERMITTED UNDER FEDERAL STATE & LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.