Material Safety Data Sheet

Biogen, Inc.                                   24-Hour Emergency Phone:
14 Cambridge Center                            1 (800) 262 4363
Cambridge, MA 02142                            Biogen Environmental Health & Safety:
(617) 679-2000                                 1 (617) 679 2236                                                                        


Section 1. Identification

Product Name: BIO1211 Chemical Name: CAS Number: None Substance: BIO 1211 is classified as an organic acid. Other Names or Code Numbers: BG9587

Section 2. Composition / Information on Ingredients

Components % Optional OSHA PEL ACGIH TLV OTHER STANDARDS BIO 1211 98% n/a n/a n/a No impurities >0.5%. No hazardous components, as defined by the OSHA Hazard Communication standard (29 CFR 1910.1200), at concentrations > 1%.

Section 3. Hazards Identification

General Statement: CAUTION: The chemical, physical, and toxicological properties of BIO 1211 have not been thoroughly investigated. Exercise due care to prevent contact or exposure. Carcinogen Status: OSHA: No NTP: No IARC: No Carcinogen Statement: Mutagenic Effects: Negative results in the Salmonella typhimurium Plate Incorporation Mutation Screen. Teratogenic Effects: Initial screens conducted in rats at dose levels up to 100 mg/kg showed no effect on fertility or fetal development. Reproductive Effects: Initial screens conducted in rats at dose levels up to 100 mg/kg showed no effect on fertility or fetal development. Neurotoxic Effects: No data available.

Section 4. First Aid Measures

If Inhaled: Remove to fresh air. Get medical attention. If breathing has stopped, give artificial respiration. Treat symptomatically and supportively. If Swallowed: Wash out with water. In Case of Skin or Eye Contact: Irritant effects may occur in the eye. Flush at least 15 minutes with water. Wash skin with soap and water, Contact a physician if irritation persists. Skin Absorption: No data available. If Injected: No data available. Medical Conditions Aggravated by Exposure: No data available.

Section 5. Fire Fighting Measures

Flash Point: No data available Flammable Limits: No data available Extinguishing Media: Use water spray, CO2, ABC dry chemical, or foam. Special Fire Fighting Materials: No special procedures. Unusual Fire and Explosion Hazards: No data available.

Section 6. Accidental Release Measures

Spill/Leak Procedures: Pick up solid material, dispose in closed container, or dissolve in water and dispose in sanitary sewer. Flush area with water and dispose in sanitary sewer. Wear gloves,safety glasses or goggles, and lab coat or coveralls to prevent contact.

Section 7. Handling and Storage

Storage: BIO1211 is moisture sensitive, degrades over period of weeks at 90% humidity conditions. Store desiccated at 2-8 °C.

Section 8. Exposure Control / Personal Protection

Perform work in a chemical fume hood or Type IIB biological Safety Cabinet, whenever possible. Follow procedures to minimize the formation of aerosols, the potential for direct skin or mucous membrane contact, or the potential for exposure by ingestion. Use personal protective equipment such as lab coat, gloves, safety glasses or goggles. Wash hands immediately upon removing gloves.

Section 9. Physical and Chemical Properties

Molecular Formula: C36H48N6O9 Molecular Weight: approximately 708 Appearance/Odor: odorless white solid; formulated material is a clear aqueous solution. Solubilities: water: 0.08 mg/mL sodium phosphate buffer: 50mM dibasic sodium phosphate buffer: 200mM to 35 mg/mL methanol, dimethylformamide Boiling Point: n/a Melting Point: decomposes 169-170 °C Vapor Pressure (mm HG): No data available Vapor Density (Air = 1): No data available Specific Gravity (H20 = 1): No data available pH: 0.08 mg/mL pH =4

Section 10. Stability and Reactivity

BIO1211 is Stable Hazardous Polymerization: Will not occur Incompatible Materials: No data Conditions to Avoid: Degrades in humid environments. Hazard Decomposition Products: No data available

Section 11. Toxicology Information

CAUTION: The chemical, physical, and toxicological properties of BIO 1211 have not been thoroughly investigated. Exercise due care to prevent contact or exposure. BIO 1211 is classified as an organic acid. It is in the earliest stages of development as an antiinflammatory agent. Single doses have been administered intravenously to rats(200mg/kg) and dogs (100mg/kg). Preliminary results suggest that intravenous dose levels up to 100 mg/kg administered daily to rats for 14 days had no adverse effects. See Section 3

Section 12. Ecological Information

BIO 1211 is not a hazardous material as defined by OSHA or EPA.

Section 13. Disposal Considerations

BIO 1211 is not a regulated hazardous material.

Section 14. Transport Information

DOT Proper Shipping Name: n/a Hazard Class: n/a ID #: n/a

Section 15. Regulatory Information

No data available.

Section 16. Other Information

MSDS Created: 26-Jul-96 Revised: 22-Apr-97 Prepared By: Susan Lee, CIH Manager, Environmental Health and Safety DISCLAIMER: The above mentioned data are based on Biogen's best present knowledge of this product. Biogen cannot guarantee completeness or accuracy of the information contained herein, and disclaims all liability for incompleteness or inaccuracy of the information and for any claims of damages arising from handling or use of this product.